spi - SPI API

Quickstart

Example: communication with a SPI data flash (half-duplex example)

# Instantiate a SPI controller
spi = SpiController()

# Configure the first interface (IF/1) of the FTDI device as a SPI master
spi.configure('ftdi://ftdi:2232h/1')

# Get a port to a SPI slave w/ /CS on A*BUS3 and SPI mode 0 @ 12MHz
slave = spi.get_port(cs=0, freq=12E6, mode=0)

# Request the JEDEC ID from the SPI slave
jedec_id = slave.exchange([0x9f], 3)

Example: communication with a remote SPI device using full-duplex mode

# Instantiate a SPI controller
# We need want to use A*BUS4 for /CS, so at least 2 /CS lines should be
# reserved for SPI, the remaining IO are available as GPIOs.
spi = SpiController(cs_count=2)

# Configure the first interface (IF/1) of the FTDI device as a SPI master
spi.configure('ftdi://ftdi:2232h/1')

# Get a port to a SPI slave w/ /CS on A*BUS4 and SPI mode 2 @ 10MHz
slave = spi.get_port(cs=1, freq=10E6, mode=2)

# Synchronous exchange with the remote SPI slave
write_buf = b'\x01\x02\x03'
read_buf = slave.exchange(write_buf, duplex=True)

Example: communication with a SPI device and an extra GPIO

# Instantiate a SPI controller
spi = SpiController()

# Configure the first interface (IF/1) of the first FTDI device as a
# SPI master
spi.configure('ftdi://::/1')

# Get a SPI port to a SPI slave w/ /CS on A*BUS3 and SPI mode 0 @ 12MHz
slave = spi.get_port(cs=0, freq=12E6, mode=0)

# Get GPIO port to manage extra pins, use A*BUS4 as GPO, A*BUS4 as GPI
gpio = spi.get_gpio()
gpio.set_direction(0x30, 0x10)

# Assert GPO pin
gpio.write(0x10)
# Write to SPI slace
slave.write(b'hello world!')
# Release GPO pin
gpio.write(0x00)
# Test GPI pin
pin = bool(gpio.read() & 0x20)

Example: managing non-byte aligned transfers

# Instantiate a SPI controller
spi = SpiController()

# Configure the first interface (IF/1) of the first FTDI device as a
# SPI master
spi.configure('ftdi://::/1')

# Get a SPI port to a SPI slave w/ /CS on A*BUS3
slave = spi.get_port(cs=0)

# write 6 first bits of a byte buffer
slave.write(b'\xff', droptail=2)

# read only 13 bits from a slave (13 clock cycles)
# only the 5 MSBs of the last byte are valid, 3 LSBs are force to zero
slave.read(2, droptail=3)

See also pyspiflash module and tests/spi.py, which provide more detailed examples on how to use the SPI API.

Classes

class pyftdi.spi.SpiPort(controller, cs, cs_hold=3, spi_mode=0)

SPI port

An SPI port is never instanciated directly: use SpiController.get_port() method to obtain an SPI port.

Example:

>>> ctrl = SpiController()
>>> ctrl.configure('ftdi://ftdi:232h/1')
>>> spi = ctrl.get_port(1)
>>> spi.set_frequency(1000000)
>>> # send 2 bytes
>>> spi.exchange([0x12, 0x34])
>>> # send 2 bytes, then receive 2 bytes
>>> out = spi.exchange([0x12, 0x34], 2)
>>> # send 2 bytes, then receive 4 bytes, manage the transaction
>>> out = spi.exchange([0x12, 0x34], 2, True, False)
>>> out.extend(spi.exchange([], 2, False, True))
property cs: int

Return the /CS index.

Return type

int

Returns

the /CS index (starting from 0)

exchange(out=b'', readlen=0, start=True, stop=True, duplex=False, droptail=0)

Perform an exchange or a transaction with the SPI slave

Parameters
  • out (Union[bytes, bytearray, Iterable[int]]) – data to send to the SPI slave, may be empty to read out data from the slave with no write.

  • readlen (int) – count of bytes to read out from the slave, may be zero to only write to the slave

  • start (bool) – whether to start an SPI transaction, i.e. activate the /CS line for the slave. Use False to resume a previously started transaction

  • stop (bool) – whether to desactivete the /CS line for the slave. Use False if the transaction should complete with a further call to exchange()

  • duplex (bool) – perform a full-duplex exchange (vs. half-duplex), i.e. bits are clocked in and out at once.

  • droptail (int) – ignore up to 7 last bits (for non-byte sized SPI accesses)

Return type

bytes

Returns

an array of bytes containing the data read out from the slave

flush()

Force the flush of the HW FIFOs

Return type

None

force_select(level=None, cs_hold=0)

Force-drive /CS signal.

This API is not designed for a regular usage, but is reserved to very specific slave devices that require non-standard SPI signalling. There are very few use cases where this API is required.

Parameters
  • level (Optional[bool]) – level to force on /CS output. This is a tri-state value. A boolean value forces the selected signal level; note that SpiPort no longer enforces that following API calls generates valid SPI signalling: use with extreme care. None triggers a pulse on /CS output, i.e. /CS is not asserted once the method returns, whatever the actual /CS level when this API is called.

  • cs_hold (float) – /CS hold duration, as a unitless value. It is not possible to control the exact duration of the pulse, as it depends on the USB bus and the FTDI frequency.

Return type

None

property frequency: float

Return the current SPI bus block

Return type

float

property mode: int

Return the current SPI mode.

Return type

int

Returns

the SPI mode

read(readlen=0, start=True, stop=True, droptail=0)

Read out bytes from the slave

Parameters
  • readlen (int) – count of bytes to read out from the slave, may be zero to only write to the slave

  • start (bool) – whether to start an SPI transaction, i.e. activate the /CS line for the slave. Use False to resume a previously started transaction

  • stop (bool) – whether to desactivete the /CS line for the slave. Use False if the transaction should complete with a further call to exchange()

  • droptail (int) – ignore up to 7 last bits (for non-byte sized SPI accesses)

Return type

bytes

Returns

an array of bytes containing the data read out from the slave

set_frequency(frequency)

Change SPI bus frequency

Parameters

frequency (float) – the new frequency in Hz

set_mode(mode, cs_hold=None)

Set or change the SPI mode to communicate with the SPI slave.

Parameters
  • mode (int) – new SPI mode

  • cs_hold (Optional[int]) – change the /CS hold duration (or keep using previous value)

Return type

None

write(out, start=True, stop=True, droptail=0)

Write bytes to the slave

Parameters
  • out (Union[bytes, bytearray, Iterable[int]]) – data to send to the SPI slave, may be empty to read out data from the slave with no write.

  • start (bool) – whether to start an SPI transaction, i.e. activate the /CS line for the slave. Use False to resume a previously started transaction

  • stop (bool) – whether to desactivete the /CS line for the slave. Use False if the transaction should complete with a further call to exchange()

  • droptail (int) – ignore up to 7 last bits (for non-byte sized SPI accesses)

Return type

None

class pyftdi.spi.SpiGpioPort(controller)

GPIO port

A SpiGpioPort instance enables to drive GPIOs wich are not reserved for SPI feature as regular GPIOs.

GPIO are managed as a bitfield. The LSBs are reserved for the SPI feature, which means that the lowest pin that can be used as a GPIO is b4:

  • b0: SPI SCLK

  • b1: SPI MOSI

  • b2: SPI MISO

  • b3: SPI CS0

  • b4: SPI CS1 or first GPIO

If more than one SPI device is used, less GPIO pins are available, see the cs_count argument of the SpiController constructor.

There is no offset bias in GPIO bit position, i.e. the first available GPIO can be reached from as 0x10.

Bitfield size depends on the FTDI device: 4432H series use 8-bit GPIO ports, while 232H and 2232H series use wide 16-bit ports.

An SpiGpio port is never instanciated directly: use SpiController.get_gpio() method to obtain the GPIO port.

property all_pins: int

Report the addressable GPIOs as a bitfield.

A true bit represents a pin which may be used as a GPIO, a false bit a reserved pin (for SPI support)

Return type

int

Returns

the bitfield of configurable GPIO pins.

property direction: int

Provide the FTDI GPIO direction.self

A true bit represents an output GPIO, a false bit an input GPIO.

Return type

int

Returns

the bitfield of direction.

property pins: int

Report the configured GPIOs as a bitfield.

A true bit represents a GPIO, a false bit a reserved or not configured pin.

Return type

int

Returns

the bitfield of configured GPIO pins.

read(with_output=False)

Read GPIO port.

Parameters

with_output (bool) – set to unmask output pins

Return type

int

Returns

the GPIO port pins as a bitfield

set_direction(pins, direction)

Change the direction of the GPIO pins.

Parameters
  • pins (int) – which GPIO pins should be reconfigured

  • direction (int) – direction bitfield (high level for output)

Return type

None

property width: int

Report the FTDI count of addressable pins.

Note that all pins, including reserved SPI ones, are reported.

Return type

int

Returns

the count of IO pins (including SPI ones).

write(value)

Write GPIO port.

Parameters

value (int) – the GPIO port pins as a bitfield

Return type

None

class pyftdi.spi.SpiController(cs_count=1, turbo=True)

SPI master.

Parameters
  • cs_count (int) – is the number of /CS lines (one per device to drive on the SPI bus)

  • turbo (bool) – increase throughput over USB bus, but may not be supported with some specific slaves

property active_channels: Set[int]

Provide the set of configured slaves /CS.

Return type

Set[int]

Returns

Set of /CS, one for each configured slaves

property channels: int

Provide the maximum count of slaves.

Return type

int

Returns

the count of pins reserved to drive the /CS signal

close(freeze=False)

Close the FTDI interface.

Parameters

freeze (bool) – if set, FTDI port is not reset to its default state on close.

Return type

None

configure(url, **kwargs)

Configure the FTDI interface as a SPI master

Parameters
  • url (Union[str, Device]) – FTDI URL string, such as ftdi://ftdi:232h/1

  • kwargs (Mapping[str, Any]) – options to configure the SPI bus

Accepted options:

  • interface: when URL is specifed as a USB device, the interface named argument can be used to select a specific port of the FTDI device, as an integer starting from 1.

  • direction a bitfield specifying the FTDI GPIO direction, where high level defines an output, and low level defines an input. Only useful to setup default IOs at start up, use SpiGpioPort to drive GPIOs. Note that pins reserved for SPI feature take precedence over any this setting.

  • initial a bitfield specifying the initial output value. Only useful to setup default IOs at start up, use SpiGpioPort to drive GPIOs.

  • frequency the SPI bus frequency in Hz. Note that each slave may reconfigure the SPI bus with a specialized frequency.

  • cs_count count of chip select signals dedicated to select SPI slave devices, starting from A*BUS3 pin

  • turbo whether to enable or disable turbo mode

  • debug to increase log verbosity, using MPSSE tracer

Return type

None

property configured: bool

Test whether the device has been properly configured.

Return type

bool

Returns

True if configured

property direction

Provide the FTDI pin direction

A true bit represents an output pin, a false bit an input pin.

Returns

the bitfield of direction.

exchange(frequency, out, readlen, cs_prolog=None, cs_epilog=None, cpol=False, cpha=False, duplex=False, droptail=0)

Perform an exchange or a transaction with the SPI slave

Parameters
  • out (Union[bytes, bytearray, Iterable[int]]) – data to send to the SPI slave, may be empty to read out data from the slave with no write.

  • readlen (int) – count of bytes to read out from the slave, may be zero to only write to the slave,

  • cs_prolog (Optional[bytes]) – the prolog MPSSE command sequence to execute before the actual exchange.

  • cs_epilog (Optional[bytes]) – the epilog MPSSE command sequence to execute after the actual exchange.

  • cpol (bool) – SPI clock polarity, derived from the SPI mode

  • cpol – SPI clock phase, derived from the SPI mode

  • duplex (bool) – perform a full-duplex exchange (vs. half-duplex), i.e. bits are clocked in and out at once or in a write-then-read manner.

  • droptail (int) – ignore up to 7 last bits (for non-byte sized SPI accesses)

Return type

bytes

Returns

bytes containing the data read out from the slave, if any

flush()

Flush the HW FIFOs.

Return type

None

force_control(frequency, sequence)

Execution an arbitrary SPI control bit sequence. Use with extreme care, as it may lead to unexpected results. Regular usage of SPI does not require to invoke this API.

Parameters

sequence (bytes) – the bit sequence to execute.

Return type

None

property frequency: float

Provides the current SPI clock frequency in Hz.

Return type

float

Returns

the SPI bus clock frequency

property frequency_max: float

Provides the maximum SPI clock frequency in Hz.

Return type

float

Returns

SPI bus clock frequency

property ftdi: pyftdi.ftdi.Ftdi

Return the Ftdi instance.

Return type

Ftdi

Returns

the Ftdi instance

get_gpio()

Retrieve the GPIO port.

Return type

SpiGpioPort

Returns

GPIO port

get_port(cs, freq=None, mode=0)

Obtain a SPI port to drive a SPI device selected by Chip Select.

Note

SPI mode 1 and 3 are not officially supported.

Parameters
  • cs (int) – chip select slot, starting from 0

  • freq (Optional[float]) – SPI bus frequency for this slave in Hz

  • mode (int) – SPI mode [0, 1, 2, 3]

Return type

SpiPort

property gpio_all_pins

Report the addressable GPIOs as a bitfield.

A true bit represents a pin which may be used as a GPIO, a false bit a reserved pin (for SPI support)

Returns

the bitfield of configurable GPIO pins.

property gpio_pins

Report the configured GPIOs as a bitfield.

A true bit represents a GPIO, a false bit a reserved or not configured pin.

Returns

the bitfield of configured GPIO pins.

property is_inverted_cpha_supported: bool

Report whether it is possible to supported CPHA=1.

Return type

bool

Returns

inverted CPHA supported (with a kludge)

read_gpio(with_output=False)

Read GPIO port

Parameters

with_output – set to unmask output pins

Return type

int

Returns

the GPIO port pins as a bitfield

set_gpio_direction(pins, direction)

Change the direction of the GPIO pins

Parameters
  • pins (int) – which GPIO pins should be reconfigured

  • direction (int) – direction bitfield (on for output)

Return type

None

terminate()

Close the FTDI interface.

Note

deprecated API, use close()

Return type

None

property width

Report the FTDI count of addressable pins.

Returns

the count of IO pins (including SPI ones).

write_gpio(value)

Write GPIO port

Parameters

value (int) – the GPIO port pins as a bitfield

Return type

None

Exceptions

exception pyftdi.spi.SpiIOError

SPI I/O error

GPIOs

See GPIOs for details

Tests

SPI sample tests expect:
  • MX25L1606E device on /CS 0, SPI mode 0

  • ADXL345 device on /CS 1, SPI mode 2

  • RFDA2125 device on /CS 2, SPI mode 0

Checkout a fresh copy from PyFtdi github repository.

See FTDI device pinout for FTDI wiring.

# optional: specify an alternative FTDI device
export FTDI_DEVICE=ftdi://ftdi:2232h/1
# optional: increase log level
export FTDI_LOGLEVEL=DEBUG
# be sure to connect the appropriate SPI slaves to the FTDI SPI bus and run
PYTHONPATH=. python3 pyftdi/tests/spi.py

Limitations

SPI Modes 1 & 3

FTDI hardware does not support cpha=1 (mode 1 and mode 3). As stated in Application Node 114:

It is recommended that designers review the SPI Slave data sheet to determine the SPI mode implementation. FTDI device can only support mode 0 and mode 2 due to the limitation of MPSSE engine.”.

Support for mode 1 and mode 3 is implemented with some workarounds, but generated signals may not be reliable: YMMV. It is only available with -H series (232H, 2232H, 4232H).

The 3-clock phase mode which has initially be designed to cope with I2C signalling is used to delay the data lines from the clock signals. A direct consequence of this workaround is that SCLK duty cycle is not longer 50% but 25% (mode 1) or 75% (mode 3). Again, support for mode 1 and mode 3 should be considered as a kludge, you’ve been warned.

Time-sensitive usage

Due to the MPSSE engine limitation, it is not possible to achieve time-controlled request sequence. In other words, if the SPI slave needs to receive command sequences at precise instants - for example ADC or DAC devices - PyFtdi use is not recommended. This limitation is likely to apply to any library that relies on FTDI device. The USB bus latency and the lack of timestamped commands always add jitter and delays, with no easy known workaround.

Wiring

SPI wiring

Fig.1: FT2232H with two SPI slaves

  • AD0 should be connected to SCLK

  • AD1 should be connected to MOSI

  • AD2 should be connected to MISO

  • AD3 should be connected to the first slave /CS.

  • AD4 should be connected to the second slave /CS, if any

  • remaining pins can be freely used as regular GPIOs.

Fig.1:

  • AD4 may be used as a regular GPIO if a single SPI slave is used

  • AD5 may be used as another /CS signal for a third slave, in this case the first available GPIO is AD6, etc.